POM copolymer Injection molding type like C 9021, with special additive modified; good chemical resistance to solvents, fuel and strong alkalis as well as good hydrolysis resistance; high resistance to thermal and oxidative degradation; good wear properties and low coefficient of friction. Reduced emission grade. Emissions according to VDA 275 < 5 mg/kg Burning rate ISO 3795 and FMVSS 302 < 100 mm/min for a thickness more than 1 mm. Ranges of applications: sliding parts for window lifter. FMVSS = Federal Motor Vehicle Safety Standard (USA) Preliminary Data Sheet
基本信息
原厂资料 | 物性表(英文) | |||
产品特性 | 耐热耐热老化耐磨低摩擦低挥发VOC抗氧化耐化学性耐水解耐碱耐燃油耐溶剂高流动共聚物降噪音 | |||
添加助剂 | 脱模剂润滑剂 | |||
成型方式 | 注塑 |
技术参数
物理性能 | 值/单位 | 测试标准 | 测试条件 |
---|---|---|---|
密度 | 1.38 g/cm³ | ISO 1183 | |
熔体体积流动速率(MVR) | |||
190℃/2.16 kg | 8 cm³/10min | ISO 1133 | |
收缩率 | |||
纵向(Flow) | 1.8 % | ISO 294-4, 2577 | |
横向(Across Flow) | 1.6 % | ISO 294-4, 2577 | |
吸水率 | 0.65 % | ISO 62 | 23°C-sat |
吸湿率 | 0.2 % | ISO 62 | 23°C/50%RH |
机械性能 | 值/单位 | 测试标准 | 测试条件 |
拉伸强度 | |||
屈服(yld) | 57 Mpa | ISO 527-2/1A | 50mm/min |
拉伸延伸率 | |||
屈服(yld) | 8 % | ISO 527-2/1A | 50mm/min |
标称断裂伸长率 | 20 % | ISO 527-2/1A | 50mm/min |
弯曲强度 | |||
- | 78 Mpa | ISO 178 | 23°C |
弯曲模量 | 2150 Mpa | ISO 178 | 23°C |
拉伸模量 | 2450 Mpa | ISO 527-2/1A | |
冲击性能 | 值/单位 | 测试标准 | 测试条件 |
简支梁缺口(Charpy Notched) | |||
-30℃ (-22℉) | 5 kJ/m² | ISO 179/1eA | |
23℃ (73℉) | 5.5 kJ/m² | ISO 179/1eA | |
简支梁无缺口(Charpy Unnotched) | |||
-30℃ (-22℉) | 110 kJ/m² | ISO 179/1eU | |
23℃ (73℉) | 130 kJ/m² | ISO 179/1eU | |
热学性能 | 值/单位 | 测试标准 | 测试条件 |
热变形温度(HDT) | |||
1.8 Mpa (264 psi)(18.6kg/cm²) | 88 °C | ISO 75-1/-2 | |
维卡软化温度(Vicat) | 145 °C | ISO 306 | 50°C/h 50N |
线性膨胀系数(CLTE) | |||
纵向(Flow) | 110 E-6/°C | ISO 11359-2 | |
熔融温度(Tm) | 166 °C | ISO 11357-1/-3 | 10°C/min |
电学性能 | 值/单位 | 测试标准 | 测试条件 |
体积电阻率 | 1.0E+12 Ohm-m | IEC 60093 | |
表面电阻率 | 1.0E+14 Ohm | IEC 60093 | |
介电常数(DK) | |||
100Hz | 3.8 - | IEC 60250 | |
1MHz | 3.8 - | IEC 60250 | |
耗散因数(DF) | |||
100Hz | 20 E-4 | IEC 60250 | |
1MHz | 50 E-4 | IEC 60250 | |
相比漏电起痕指数(CTI ) | |||
- | 600 - | IEC 60112 | |
绝缘强度 | 35 kV/mm | IEC 60243-1 |